Mini One Specifications

Build 2011-6:

Dehumidification Capacity at ambient conditions of 22ºC, 65% RH: > 6 gm/hour (basis 30% RH output)
Humidification Capacity at ambient conditions of 22ºC, 35% RH: >9.5 gm/hour (basis 85% RH output)
Humidification Capacity from dry (eg dry nitrogen feed) conditions of 22ºC, 5% RH: >9.5 gm/hour; (basis 55% RH output)
Treatment Capacity is a result of complex interactions of enclosure characteristics, ambient conditions, and appropriate unit configuration and installation. Please Inquire

Maximum Power Consumption: 240 Watts

Typical Power Consumption: 100 Watts

Power Source:  105 ? 120 or 210 ? 230 Volts, 50 or 60 Hz

System Internal Voltage: 12 Volts DC

Shipping Weight: 14 kg (31 lb)

Output Humidity: Variable airflow of 30% to 80% RH as needed to achieve target, automatically switching to constant airflow, typically variable +/- 1% @ 22 degrees C

Output Volume: 24 cubic meters / day (850 cubic feet / day) ? typical @ 60 Hz (may be increased to up to 50 cubic meters / day (1600 cubic feet / day) with Treatment Capacity Booster)

Output Pressure: < 2.5 inches H2O / 600 Pa

Multiple Feeds: Single unit may feed many showcases (Optional)

Operating Temperatures: 15 to 27 degrees C (60 to 80 degrees F) (Ambient temperatures will affect control capacities)

Sensor Element: Capacitive thin film sensor

Sensor Reading Accuracy: +/-2% over mid range

Sensor Repetitive Accuracy: +/-1% Automatic pump shut-off, typically triggered at +/- 5% from target (adjustable) to isolate showcase

Pollution Filters: (Optional) In line activated carbon, or as operator specified

Communication: RS- 485 for data capture and unit control (with optional software)

Data Logging: Direct to removable SD card

Onboard Reservoir Capacity: 2 liters

External Reservoir Capacity: unlimited

Water level Indicator: Three LED indicators on front panel (Low, Medium, High)

Low Water Alarms: Panel LED and remote LED indicator on flexible lead

Remote Reservoir Fill Pump: 12 vDC powered contacts to replenish reservoir via remote pump (optional)

RH Alarm Indicator: Panel LED and remote LED indicator on flexible lead

Biocides: Copper components, chilled compartments and TiO2 mesh

Installation Options: Modules may be stacked, placed adjacent to each other, or separated by up to 10 m (30 ft) or more. Neither module need be in the controlled showcase.

Standard Components: Unit consists of humidity adjustment module, a pump module, one sensor, supply hoses, signal and power cable(s), operator?s manual

Positive Pressure Mode: A single air supply tube and inlet port is used. Showcase inlet port size: > 10 mm (0.25?) min diameter. Do not block inlet or airflow into vitrine. Pressure relief holes or air exits in the showcase are NOT necessary
Recirculating Mode (Optional) An additional outlet port and air return line from the showcase to the pump module may be used to reduce water consumption.

Control Module Dimensions: W 39.5 cm (15.5 in) X D 40.7 cm (16 in) X H 18.3 cm (7.2 in)  Unit will need clearance for ventilation and connections 

Pump Module Dimensions: W 14.6 (5.75 in) X D 15.3 cm (6 in) X H 8.9 cm (3.5 in)

Sensor Dimensions: 6 mm (1/4 in) OD X 50 mm (4 in); Cable Length: 1.8 m (6 ft)

Installation Footprint: Main Unit: W 45 cm (18 in) (includes 2.5 cm at each side) X D 50 cm (20 in) (includes 1 cm rear and 11 cm front). Add 4 cm (6 in) to width for pump (unless remotely located, or placed on top of Control Module)
Vertical Dimensions: 19 cm (7.5 in) in when pump is remote or adjacent to main unit. Total H is 28 cm (13 in) when pump module is located upon top of main module. See installation manual for details 

Ventilation: Appropriate air vents must be supplied and exhaust hose connected as per operator?s manual

Drainage: Condensate will be directed to a drip pan (not supplied). In almost all situations, this will evaporate quickly into the unit?s exhaust air, and no drain will be required.